Comprehensive Characterization of Injectable Platelet-Rich Fibrin (i-PRF): Cellular, Biochemical, Architectural, Rheological, and Release-Kinetic Profiling of Ten Independent Preparations

Packkyarathinam, Rathinavelpandian Perunchezhian and Jeyaraman, Naveen and Muruganandam, Anandanarayan and Venkatasalam, Ravichandran and Nallakumarasamy, Arulkumar and Muthu, Sathish and Rajendran, Sree Naga Sowndary and Gangadaran, Prakash and Jeyaraman, Madhan (2026) Comprehensive Characterization of Injectable Platelet-Rich Fibrin (i-PRF): Cellular, Biochemical, Architectural, Rheological, and Release-Kinetic Profiling of Ten Independent Preparations. Biologics, 6 (4). p. 37. ISSN 2673-8449

[thumbnail of biologics-06-00037.pdf] Text
biologics-06-00037.pdf - Published Version
Available under License Creative Commons Attribution.

Download (6MB)

Abstract

Background: Injectable platelet-rich fibrin (i-PRF) is a second-generation autologous platelet concentrate from low-speed centrifugation of whole blood without the use of any anticoagulant. However, despite the growing use in the clinic, there are few studies that have combined data from cellular to biochemical, ultrastructural, rheological, and release-kinetic descriptors in a single cohort. Objective: To characterise i-PRF from 10 healthy donors for each of 8 pre-defined domains and determine preliminary reference physico-chemical parameters relevant to the bioactivity and injectability. Methods: Ten i-PRF preparations were made using the Low-Speed Centrifugation Concept (700 rpm, 60 g, 3 min). Samples were analysed by cellular profiling (automated haematology, flow cytometry); growth-factor measurements by ELISA and Luminex (PDGF-AA/AB/BB, VEGF, TGF-β1, IGF-1, EGF, FGF-2, HGF, BMP-2/7); ultrastructural analysis (scanning electron microscopy); clot kinetic assessment; oscillatory rheometry; and 14-day cumulative release kinetics. Results: The mean platelet enrichment was 940 ± 56 × 103/µL, leukocytes 25.5 ± 2.7 × 103/µL, and no significant erythrocytes were seen. TGF-β1 (42.0 ± 3.3 ng/mL) and IGF-1 (82.4 ± 9.1 ng/mL) dominated; BMP-2 and BMP-7 were detected at lower concentrations (65.7 ± 9.4 and 40.3 ± 6.8 pg/mL, respectively); VEGF and PDGF-BB showed inter-sample CVs below 10%. Fibrin fibre thickness was 142 ± 13 nm and porosity 68.9 ± 2.9%. The values for storage modulus G′ (133 ± 11 Pa) and tan δ (0.19) indicate a soft elastic gel. In phosphate-buffered saline, cumulative release continued until day 14, with 46% released by day 3 and >90% by day 10. Conclusions: i-PRF prepared according to the low-speed concept provided, under the present single-protocol conditions, a biologic with consistent cellular, biochemical, ultrastructural and rheological signatures suitable for a minimally invasive injectable format. These findings should be regarded as preliminary, protocol-specific reference data that require confirmation in larger donor cohorts and functional studies.

Item Type: Article
Subjects: Platelet-rich plasma
Divisions: Regenerative Medicine
Depositing User: Mr Repository Admin
Date Deposited: 25 Nov 2026 16:34
Last Modified: 26 Nov 2026 07:55
URI: https://ir.orthopaedicresearchgroup.com/id/eprint/793

Actions (login required)

View Item
View Item